Windows 7 64-bit VXI Firewire

Windows 7 support for VXI on 64 bit systems using a Firewire interface (8491B. New Agilent IO Library drivers included (v.16.2)

New LANXI driver

The LAN-XI driver for I-deas supports PULSE 16 and 16.1 and the new 3053 (12-channel) module. The install is found under the tda\BK_PULSE\Install folder in the I-deas installation. Support for previous versions of PULSE can be downloaded from the B&K web site (www.bksv.com).

Support for Windows Server 2008R2

Updated Licensing to FlexLM version 11.10 to support Windows Server 2008R2

New version of Nastran Importers

A new version of The Nastran Importers is included on the Update Disk under Addtional software. The new version has been updated to support NX NASTRAN 8.0 and MSC NASTRAN 2010.

FEM Calibrator

This release includes the following enhancements:

  • Updated to support the latest NASTRAN versions.
  • Fixes for a number of bugs

Bug Fixes

  • Corrected problem with licensing where when TFI and Pulse are installed on the same system and the user removed Pulse, files required by the TFI license manager would also get removed.
  • Corrected problems with licensing where an install of Pulse and TFI on the same system would cause the license manager to crash (BKSV.exe).
  • The “Rejected” message on the Real Time Displays was not cleared when a frame was accepted.
  • Fixed FFT leakage problems when using the Impact Window when the data had a DC offset. A DC offset removal is now done using the first value in the measured frame. This avoids FFT leakage by effectively forcing the first and last values of the frame to be zero.
  • Transducers attached to Virtual Channels were being lost or reset upon returning from the Channel Table Spreadsheet.
  • The burst random “Duration %” and “Off Time %” were not being set up correctly. This has been fixed including setting a long Off Time % to create a delay between bursts.
  • Prevent a crash the occurred when the Universal file dataset 58b (binary) read was performed on a truncated file.
  • Avoid a read failure for a dataset 58 read when both the response node and direction are 0.